Design, Supply, Installation, Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service - On-Grid system without battery, Hybrid with battery storage; as per requirement; as per requirement
Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
No organisation data
Try another outcome or period.
No state data
Try another outcome or period.
Design, Supply, Installation, Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service - On-Grid system without battery, Hybrid with battery storage; as per requirement; as per requirement
Microprocessor Release MCCB, 100 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 160 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 250 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 400 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 630 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, HRC Fuse Bolted Fuse Links, 2 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 4 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 6 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 16 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 6026, HRC Fuse Bolted Fuse Links, 32A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1 IEC 60269-, HRC Fuse DIN Type, 63 A, 415 V, HN Type, SIZE-000 IEC 60269-2, IS 13703 Part 2, Breaking Capacity-100kA, HRC Fuse DIN Type, 100 A, 415 V, HN Type, SIZE-00 IEC 60269-2, IS 13703 Part 2; Breaking Capacity-100k, HRC Fuse DIN Type, 125 A, 415 V, HN Type, SIZE-00 IEC 60269-2, IS 13703 Part 2; Breaking Capacity-100k, RCBO(ELCB+ MCB) , 2P, 10A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 2P, 16A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking C, RCBO(ELCB+ MCB) , 2P, 32 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 16 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 32 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 63 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, MCB, 10 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 16 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 16 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 4P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 4P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2
Design, Supply, Installation, Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service - On-Grid system without battery, Hybrid with battery storage; as per requirement; as per requirement
Microprocessor Release MCCB, 100 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 160 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 250 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 400 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, Microprocessor Release MCCB, 630 A, 3P, 415 V, 50Hz 50/55 Ka Conforms To IS/IEC 60947-2, HRC Fuse Bolted Fuse Links, 2 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 4 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 6 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 60269, HRC Fuse Bolted Fuse Links, 16 A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1/IEC 6026, HRC Fuse Bolted Fuse Links, 32A, 415 V, HG Type/Offset Staggered/Offset Blade Tag, SIZE-F1 IEC 60269-, HRC Fuse DIN Type, 63 A, 415 V, HN Type, SIZE-000 IEC 60269-2, IS 13703 Part 2, Breaking Capacity-100kA, HRC Fuse DIN Type, 100 A, 415 V, HN Type, SIZE-00 IEC 60269-2, IS 13703 Part 2; Breaking Capacity-100k, HRC Fuse DIN Type, 125 A, 415 V, HN Type, SIZE-00 IEC 60269-2, IS 13703 Part 2; Breaking Capacity-100k, RCBO(ELCB+ MCB) , 2P, 10A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 2P, 16A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking C, RCBO(ELCB+ MCB) , 2P, 32 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 16 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 32 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, RCBO(ELCB+ MCB) , 4P, 63 A, 300mA Conforms To IEC 61009-1, IS 12640-2, EN 61009- 1; Short Circuit Breaking, MCB, 10 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 16 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 2P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 16 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 3P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 32 A, 4P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2, MCB, 63 A, 4P, 415 V, 10kA, C Series-IS/IEC 60898 - 10kA; IEC/IS 60947-2
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.