Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
No organisation data
Try another outcome or period.
No state data
Try another outcome or period.
inverters solar inverter Inverters Solar Inverter ( 60 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating of inverter (KVA) 2.0 KVA 2.0 KVA ISI marked Yes Yes If ISI marked yes, CM/L No. must declare. If ISI mark No write NA no - Nos. of phase single single Inverter output wave form Pure sine wave Pure sine wave Ingress protection rating of inverter IP 23 for indoor use IP 23 for indoor use Built in protection for AC high/low voltage and frequency if connected to AC mains IP 23 for indoor use IP 23 for indoor use Display Type LCD LCD Area required for installation of Solar panels with mounting structure (sq. mt) 12 - Material of mounting structure Stainless steel Galvanised steel, Stainless steel 1/5 CONSTRUCTIONAL Mode of operation To be used in conjunction with AC mains - Switching device IGBT MOSFET, IGBT Maximum power point tracking (MPPT) yes - Galvanic isolation between input DC and output AC yes - By-pass facility if connected to AC mains IP 23 for indoor use - Display parameters like DC voltage (V) DC current (A) AC voltage(V) YES - Sequence of power drawing (1) SPV (2) AC MAINS (IF CONNECTED WITH AC POWER) (3) BATTERY BANK - Nos. of modules in an array (NOS.) 8 - Rating of individual PV module (Wp) 250 - Salt mist corrosion resistant material for body and frame of SPV module Galvanized steel Galvanized steel, Aluminium Provision for Solar generation meter yes - Provision for bidirectional meter (Net Meter) yes - Provision of anti rusting/non corrosive mounting structure yes - Sustainability of wind speed. (KM/Hr) 200 200, 150 Type of battery (KM/Hr) SMF Tubular Gel, SMF Capacity of battery bank (VAH) 150 - 3 stage battery charging (float, boost and equalize stage) for long life of the battery yes - Reverse polarity protection yes - 2/5 Complete installation work to be done by supplier yes - Gross weight of the inverter (kg) 15 - Reverse polarity protection for PV modules yes - FUNCTIONAL Inverter efficiency 70% - Total Harmonic distortion (%) 3 - Operating AC voltage range (Volts) 220 - Operating frequency range (Hz) 50 - Operating Temperature (degree cel) 45 - Operating relative humidity (%) 12 - Load power factor 0.8 - Output regulation at rated voltage Yes - Over load Protection 110% for 60 Seconds, 125% for 30 Seconds and 150% for 5 seconds yes - Efficiency of Solar panel (%) 16 - Battery backup time at rated load (Hour) 2 2 Battery bank Voltage (Volt) 24 - CERTIFICATIONS Conformity of inverter to environmental testing conditions as per IEC 600688-2 (1, 2, 14, 30) or equivalent BIS standard YES - 90% performance warranty for SPV (years) 10 - 80% performance warranty for SPV (years) 25 - TTC for PV module from any MNRE lab as per MNRE 2015-2016 yes - 3/5 OEM test report for indigenously produced PV module (s) yes - Availability of Type test report for inverter including environmental tests from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification yes - Test report number 47870921522.1.1-NABL- MNRE-52 - Date of test report 31.03.2016 - Name and address of laboratory URL India Pvt. Ltd. - Type test report to be furnished on buyers demand yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SUBRATA SAHA ROY 263645, O/o The Inspector General, Ftr Hqrs, SSB Ranikhet, Ganiyadeoli, PO.Ranikhet 60 30
inverters solar inverter Inverters Solar Inverter ( 60 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating of inverter (KVA) 2.0 KVA 2.0 KVA ISI marked Yes Yes If ISI marked yes, CM/L No. must declare. If ISI mark No write NA no - Nos. of phase single single Inverter output wave form Pure sine wave Pure sine wave Ingress protection rating of inverter IP 23 for indoor use IP 23 for indoor use Built in protection for AC high/low voltage and frequency if connected to AC mains IP 23 for indoor use IP 23 for indoor use Display Type LCD LCD Area required for installation of Solar panels with mounting structure (sq. mt) 12 - Material of mounting structure Stainless steel Galvanised steel, Stainless steel 1/5 CONSTRUCTIONAL Mode of operation To be used in conjunction with AC mains - Switching device IGBT MOSFET, IGBT Maximum power point tracking (MPPT) yes - Galvanic isolation between input DC and output AC yes - By-pass facility if connected to AC mains IP 23 for indoor use - Display parameters like DC voltage (V) DC current (A) AC voltage(V) YES - Sequence of power drawing (1) SPV (2) AC MAINS (IF CONNECTED WITH AC POWER) (3) BATTERY BANK - Nos. of modules in an array (NOS.) 8 - Rating of individual PV module (Wp) 250 - Salt mist corrosion resistant material for body and frame of SPV module Galvanized steel Galvanized steel, Aluminium Provision for Solar generation meter yes - Provision for bidirectional meter (Net Meter) yes - Provision of anti rusting/non corrosive mounting structure yes - Sustainability of wind speed. (KM/Hr) 200 200, 150 Type of battery (KM/Hr) SMF Tubular Gel, SMF Capacity of battery bank (VAH) 150 - 3 stage battery charging (float, boost and equalize stage) for long life of the battery yes - Reverse polarity protection yes - 2/5 Complete installation work to be done by supplier yes - Gross weight of the inverter (kg) 15 - Reverse polarity protection for PV modules yes - FUNCTIONAL Inverter efficiency 70% - Total Harmonic distortion (%) 3 - Operating AC voltage range (Volts) 220 - Operating frequency range (Hz) 50 - Operating Temperature (degree cel) 45 - Operating relative humidity (%) 12 - Load power factor 0.8 - Output regulation at rated voltage Yes - Over load Protection 110% for 60 Seconds, 125% for 30 Seconds and 150% for 5 seconds yes - Efficiency of Solar panel (%) 16 - Battery backup time at rated load (Hour) 2 2 Battery bank Voltage (Volt) 24 - CERTIFICATIONS Conformity of inverter to environmental testing conditions as per IEC 600688-2 (1, 2, 14, 30) or equivalent BIS standard YES - 90% performance warranty for SPV (years) 10 - 80% performance warranty for SPV (years) 25 - TTC for PV module from any MNRE lab as per MNRE 2015-2016 yes - 3/5 OEM test report for indigenously produced PV module (s) yes - Availability of Type test report for inverter including environmental tests from Central government/NABL/ILAC accridiated laboratory to prove conformity to the specification yes - Test report number 47870921522.1.1-NABL- MNRE-52 - Date of test report 31.03.2016 - Name and address of laboratory URL India Pvt. Ltd. - Type test report to be furnished on buyers demand yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SUBRATA SAHA ROY 263645, O/o The Inspector General, Ftr Hqrs, SSB Ranikhet, Ganiyadeoli, PO.Ranikhet 60 30
1 more tender is hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.