NEEDLES AND SYRINGES DESTROYER NEEDLES AND SYRINGES DESTROYER ( 76 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Purpose To destroy the used injection needles by instant electromelting process and to cut syringe tips manually using the appliance - Type Portable and electrical Portable and electrical, Portable and Manual Principle of operation Electro-melting type Electro-melting type, manual cutting type CONSTRUCTION Suitable sliding tray shall be provided for collection of residue and destroyed syringe tips yes - Material of the Housing/enclosure ABS Plastic ABS Plastic, Glass filled nylon Housing/enclosure shall be moulded type and shock proof yes - Provision to burn the needles and to cut the syringe tips shall be provided in the unit yes - Manual cutter provided in the equipment Made of hardened blade of anti-corrossive - 1/4 SS material Transformer winding NA Aluminium, Copper, NA FUNCTIONAL Number of needles of 1mm dia and 80mm length that can be destroyed in continuous operation of 5 minutes 500 - Sizes of injection needles of all kinds which can be destroyed Dia Ranging from 0.4mm to 1.6mm (26 SWG to 14 SWG) with length 12.5mm to 80mm Dia Ranging from 0.4mm to 1.6mm (26 SWG to 14 SWG) with length 12.5mm to 80mm, Dia Ranging from 0.4mm to 1.0mm (26 SWG to 18 SWG) with length 12.5mm to 80mm ELECTRICAL Power supply 207V to 253V, 50Hz AC supply 207V to 253V, 50Hz AC supply, NA Power ON/OFF switch with indicator shall be provided YES YES, NA Rated power(Watts) 60 60, 100 Shall be provided with fuse and power cord of min 3m length and earthing point NA YES, NA Manual of usage instructions To be supplied by the supplier - CERTIFICATIONS Availability of Certification for the product to ISO-13485-2009 from Govt approve Lab YES - Comply in general to IS:302Pt-1/1979 to ensure safe and reliable operation in normal use YES - Occupational health and safety certification from approved bodies as per OHSAS 18001-2007 YES - CE Certification from approved bodies true - TESTS & REPORTS Safety tests shall consist of YES - 2/4 marking, protection against electric shock, temperature rise, IR, Leakage current, HV, Stability and mechanical hazards, mechanical strength, constructional requirements, creepage distance and clearances, resistance to heat, fire and tracking as per IS:302Pt-1/79 Performance tests shall consist of capacity test as per clause 14 above, power consumption test at maximum load and ability to cut syringe tips YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shashi kant 249201, Virbhadra Road, Shivaji Nagar, Near Bairaj Lake, Rishikesh, Uttarakhand 76 15
Loading…