Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; MOTOR-Complete Overhauling of horizontal/Vertical pump Motor of rating 31 to 99 KW for details refer BOQ Item No 9; As per Scope.., Repair, Maintenance, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; MOTOR Complete Overhauling of horizontal/Vertical pump Motor of rating 100 to 400 KW for details refer BOQ Item No 10; As per Sc.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Complete overhauling of valves (Gate valve, Globe valve, check valve, Diaphragm valve, Control valve including actuator) si.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE- Complete overhauling of valves (Gate valve, Control valve including actuator) s.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Complete overhauling of Butterfly valves along with Actuators of sizes 150mm to 300 mm NB Active/Non active for details r.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE- Complete overhauling of Butterfly valves along with Actuators of sizes 350 mm to 450 mm NB for details refer BOQ Item No 1.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Complete overhauling of Butterfly valves along with Actuators of sizes 500 mm to 800 mm NB for details refer BOQ Item No 16.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER-Cleaning of Y-type strainer of sizes :- 80mm to 200 mm NB for details refer BOQ Item No 17; As per Scope of work and ATC, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER- Cleaning of Y-type strainer of sizes 250mm to 400 mm NB for details refer BOQ Item No 18; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER-Cleaning of Basket-type strainer (inside pipe spool) of sizes 500 mm to 800 mm NB for details refer BOQ Item No 19; As p.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 50 to 200 mm NB.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE- Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 250mm to 450 m.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 500 to 600 mm N.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 1000 to 1500 mm.., and Installation of Plant/Systems/Equipments, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Dismantling tube cleaning by Hydro jet assembly and testing of Heat Exchanger of Condenser Vacuum HX Stator water cooler Turbi.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Gasket replacement and Cleaning of Small drain expander for details refer BOQ Item No 26; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Gasket replacement and Cleaning of Large drain expander for details refer BOQ Item No 27; As per Scope of work and ATC, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; IDCT Cleaning or replacement of spray nozzle in Induced draft cooling tower 1 set = 5928 Nos for details refer BOQ Item No 28; As.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT Cleaning or replacement of spray nozzle in Natural draft cooling tower 1 set = 6636 Nos for details refer BOQ Item No 29; As.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT Cleaning flushing and replacement of O ring or end cap in Natural draft cooling tower 1 Set=344 Nos for details refer BOQ It.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT or IDCT screen removal cleaning and installation of RAPS 3 and 4 1 set = 4 Nos for details refer BOQ Item No 31; As per Scop.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of check valve or manual isolating valve or relief valve of High Energy System of size less than and equal to 5.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Overhauling of check valve manual isolating valve/relief valve of High Energy System of size 65 NB to 150 NB (TG & Feed .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Overhauling of check valve/manual isolating valve/relief valve of High Energy System of size 200 NB to 350 NB size (TG & .., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes less than and equal to 50 NB x 600 or 800 lbs .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes 65 NB to 150 NB x 600 or 800 lbs rating .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes 200 NB to 300 NB x 600 or 800 lbs rating.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete MVs with electrical actuator of High Energy System of sizes 65 NB to 150 NB x 600 or 800 lbs rating.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete MVs with electrical actuator of High Energy System of sizes 200 NB to 400 NB x 600 or 800 lbs ratin.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of CVs pneumatic actuator or MVs electrical actuator of sizes less than and equal to 150 NB for details refer B.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of CVs pneumatic actuator or MVs electrical actuator of sizes 200 NB to 400 NB for details refer BOQ Item No 42.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; Consumables required for maintenance per BSD as per scope of work for details refer BOQ Item No 43; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Cleaning of tubes of Main Condenser by Hydro jet cleaning method 1 set = 18938 tubes of 25 mm OD x 13 point 5 meter long for d..
Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; MOTOR-Complete Overhauling of horizontal/Vertical pump Motor of rating 31 to 99 KW for details refer BOQ Item No 9; As per Scope.., Repair, Maintenance, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; MOTOR Complete Overhauling of horizontal/Vertical pump Motor of rating 100 to 400 KW for details refer BOQ Item No 10; As per Sc.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Complete overhauling of valves (Gate valve, Globe valve, check valve, Diaphragm valve, Control valve including actuator) si.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE- Complete overhauling of valves (Gate valve, Control valve including actuator) s.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Complete overhauling of Butterfly valves along with Actuators of sizes 150mm to 300 mm NB Active/Non active for details r.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE- Complete overhauling of Butterfly valves along with Actuators of sizes 350 mm to 450 mm NB for details refer BOQ Item No 1.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Complete overhauling of Butterfly valves along with Actuators of sizes 500 mm to 800 mm NB for details refer BOQ Item No 16.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER-Cleaning of Y-type strainer of sizes :- 80mm to 200 mm NB for details refer BOQ Item No 17; As per Scope of work and ATC, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER- Cleaning of Y-type strainer of sizes 250mm to 400 mm NB for details refer BOQ Item No 18; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; STRAINER-Cleaning of Basket-type strainer (inside pipe spool) of sizes 500 mm to 800 mm NB for details refer BOQ Item No 19; As p.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 50 to 200 mm NB.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE- Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 250mm to 450 m.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 500 to 600 mm N.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; FLANGE-Gasket replacement in Flange/blind flanges of sizes :- (Including opening/closing & cleaning of flanges) 1000 to 1500 mm.., and Installation of Plant/Systems/Equipments, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Dismantling tube cleaning by Hydro jet assembly and testing of Heat Exchanger of Condenser Vacuum HX Stator water cooler Turbi.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Gasket replacement and Cleaning of Small drain expander for details refer BOQ Item No 26; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Gasket replacement and Cleaning of Large drain expander for details refer BOQ Item No 27; As per Scope of work and ATC, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; IDCT Cleaning or replacement of spray nozzle in Induced draft cooling tower 1 set = 5928 Nos for details refer BOQ Item No 28; As.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT Cleaning or replacement of spray nozzle in Natural draft cooling tower 1 set = 6636 Nos for details refer BOQ Item No 29; As.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT Cleaning flushing and replacement of O ring or end cap in Natural draft cooling tower 1 Set=344 Nos for details refer BOQ It.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; NDCT or IDCT screen removal cleaning and installation of RAPS 3 and 4 1 set = 4 Nos for details refer BOQ Item No 31; As per Scop.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of check valve or manual isolating valve or relief valve of High Energy System of size less than and equal to 5.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Overhauling of check valve manual isolating valve/relief valve of High Energy System of size 65 NB to 150 NB (TG & Feed .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE-Overhauling of check valve/manual isolating valve/relief valve of High Energy System of size 200 NB to 350 NB size (TG & .., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes less than and equal to 50 NB x 600 or 800 lbs .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes 65 NB to 150 NB x 600 or 800 lbs rating .., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete CVs with pneumatic actuator of High Energy System of sizes 200 NB to 300 NB x 600 or 800 lbs rating.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan, and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete MVs with electrical actuator of High Energy System of sizes 65 NB to 150 NB x 600 or 800 lbs rating.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of complete MVs with electrical actuator of High Energy System of sizes 200 NB to 400 NB x 600 or 800 lbs ratin.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of CVs pneumatic actuator or MVs electrical actuator of sizes less than and equal to 150 NB for details refer B.., and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; VALVE Overhauling of CVs pneumatic actuator or MVs electrical actuator of sizes 200 NB to 400 NB for details refer BOQ Item No 42.., and Installation of Plant/Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; Consumables required for maintenance per BSD as per scope of work for details refer BOQ Item No 43; As per Scope of work and ATC, and Installation of Plant Systems/Equipments (Version 2) - Rawatbhata Rajasthan Site Unit-3 and 4; HX Cleaning of tubes of Main Condenser by Hydro jet cleaning method 1 set = 18938 tubes of 25 mm OD x 13 point 5 meter long for d..
2 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.