door frame metal detector dfmd security metal detector Door Frame Metal Detector Dfmd Security Metal Detector ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/CAPACITY Type of usage Outdoor Indoor, Outdoor Detection Zones Multiple Zone Single Zone, Multiple Zone Function Detects Ferrous, Non- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way * Number of Horizontal Detection Zones covering full Height 12 * Capacity/throughput rate (person/min) 30 or more * False Alarm rate (%) 3 * DIMENSIONS/WEIGHT Passage Height 2100 * Passage Breadth 750 * Passage Width 570 * 1/6 Weight of the equipment Not more than 80 Kg * DOOR FRAME CONSTRUCTION Construction of Door Frame (Walk-through Arch) Light weight, rigid, laminated side panels and cross piece with ABS plastic boots for panel protection * Material of Walk- through Arch WOOD * Provided with base wheels for easy mobility false * Provided with a floor panel to attach both side panels to give stability & rigidity to the structure false * Ramp over the floor panel - Covered with synthetic carpet for long life false * Water proof false * Weather proof false * DETECTION Metals detectable Ferrous, Non-Ferrous, Ferrite & Alloys * Uniform Detection from top to bottom Yes * Capable of Metal Detection in all orientations Yes * Detect multiple objects of various size, weight and shape in all the zones simultaneously from head to toe Yes * Capable of Metal Detection in walking speed of interception Yes * Performance independent of the speed of person passing through Yes * ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes * Audible Alarm on detection with adjustable volume Yes * 2/6 Bar Display to indicate Metal location w r t Height on person Yes * Audio-Visual Low Battery indication Yes * Back-lit Display LED * SENSITIVITY Operational Frequencies User selectable * Number of User Selectable frequencies 5 * Adjustable Sensitivity Yes * Number of Sensitivity Levels/Steps 12 * Uniform Sensitivity in all zones Yes * Calibration Both manual and Auto Calibration * SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes * Re-setting after alarm condition Re-set itself (auto) within 3 Seconds * Walk/Stop indicator for traffic control Yes * Control Panel Easy accessible control panel, with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. * User friendly self- testing diagnostics to identify faulty condition Yes * INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs Do not interfere with adjacent installed DFMDs located close to each other upto a distance of 1 * Static Metal Compensation Not affected by heavily reinforced floors/roof Yes * 3/6 tops/walls High discrimination between small masses and personal metallic objects Yes * Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes * Not affected by by interference, which is mains-borne or radiated by external source Yes * Not affected by the operation of radio, Mobile phones, walkie- talkie sets, X-ray monitors etc within a distance of one meter Yes * Not affected by moving metallic items such as trolleys, opening closing of metallic gate etc, one meter away from the archway Yes * HEALTH & SAFETY Harmless to wearers of pacemakers, defibrillators or other vital support systems, pregnant women and magnetic storage media Yes * Not affected by infrared, ultraviolet, electromagnetic or RF radiation Yes * Conform to international security standards of Safety Radiation Yes * Harmless to magnetic media, electronic devices, Film safe and Data safe Yes * ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C * Operating Humidity - Non condensing (RH) (%) 90 * 4/6 POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery * Power Supply 220 V +/-10% VAC * Battery Re-chargeable, maintenance free, internal battery with charger * Battery Back-up in full function (hours) 10 * ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply * Training tools- Charts, slides, training brochure, training work model, blowup diagram, video films on demonstration and use etc Inclusive in the scope of supply * Technical manual giving full description of the item, user's handbook and literature Yes * Practical training At least one day in each quarter of the year continuing during warranty period * Availability of Spares for a period of 7 years after the warranty period true * Ruggedized polypropylene shock proof container compliant to IP 65 or better for safe transportation of the equipment true * WARRANTY Warranty (Years) 3 * CERTIFICATION Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification true * 5/6 Test Report Number & Date - * Name & address of the Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Hareesh T 172107, 136 (I) Inf Bde Gp OMC Near Shongthong Bridge Poari 2 15
Loading…