glucose monitors or meters-Glucometer Glucose Monitors Or Meters-Glucometer ( 13400 ) Technical Specifications Specification Specification Name Values Allowed Values COMPLETE SET Availability of Glucostrip & Lancet in open market all over India Yes - Operating Relative humidity (%) 15 to 90 - Number of sets of Glucostrip and lancet in a bundle 50 25, 50, 100, 200 Availability of safety certifications - FDA (US)/CE (EU) -- BIS/ISO:13485 & ISO: 15197 FDA (US), CE (EU) FDA (US), CE (EU) Size of LCD display digits (mm) 32 Inbuilt software for accurate measurement Yes - Auto-shut off of device when not in use Yes - Needle fully shielded before and after use Yes - Accuracy of device (%) 9 1/4 Calibre stick appropriate for 500 tests Yes - Number of tests on one battery (No. of Test results) 1000 - Weight of device 50 Operating Temp 0 to 55 Degree Celcius - Warranty of device (Years) 2 1, 2, 3 Reproducibility of device (%) 4.5 Facility for Data transfer through USB device true - Operating Manual of device Yes - Single use pressure activated autodisable Safety Lancet Yes - Technology of device Electrochemical - Size of blood sample (Micro litre) 0.5 Shelf life of gluco strips (Months) at the time of supply 18 Penetration depth to suit capillary requirement Adjustable Adjustable, Fixed Retraction of needle into casing after sampling Automatic - Protection from blood borne infections Yes - Number of cells (nos) 1 - Display of time & amp; date Yes - Reading time of device 10 Display of sugar in mg/dl Yes - Automatic code detection of Glucostrip Yes - Battery Type LITHIUM - Life of Gluco-strips after opening of 12 2/4 container Dimensions of the Device (Length(L) xWidth(W) x Height (H) 2X1X3 - Range/Linearity of device (mg/dl) 30 to 700(Min.) - Memory capacity of device (Test results) 300 Whole device should be cleanable and sterlizable with alcohol Yes - Control solution/Calibre for 500 tests Yes - Availability Of Type Test Reports(TTRs) of the Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification, If TTRs available must furnish details (No, Date and Name of Laboratory) of the same Yes - Date of test report by laboratory 31-05-2016 - Test report number 87/BCL/2016 - Name, address and contact number/email of the laboratory NATIONAL INSTITUTE OF BIOLOGICALS ( MINISTRY OF HEALTH AND FAMILY), A-32, SECTOR 62, INSTITUTIONAL AREA NOIDA-201309, 0120-2400022, [email protected] - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DEBABRATA DE 723121, Divisional General Stores Depot, Mama More, P.O.-Adra District-Purulia West Bengal Pin - 723121. 13400 15 EMD Required No 3/4 ePBG Required No
Loading…