Emergency lighting and accessories (Portable Emergency Lighting System Tower type with Battery Bank Emergency Lighting And Accessories (Portable Emergency Lighting System Tower Type With Battery Bank ( 50 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Portable emergency lighting system consisting Rechargeable Battery Bank, Charging unit with charging cables, Mobile (from vehicle) charging kit and cables, Tower/Telescopic collapsible mast/Vertical mast, LED Luminaire, Supporting kits, Tool Kits, Storage box for tool kits (Tool kit list to be furnih by seller at the time of supply) Yes * Type of battery Rechargeable * Chemistry of battery SMF Lead acid battery SMF Lead acid battery, 1/7 Lithium ion Battery capacity (minimum) 12 Ah * Minimum continuous working hours 18 hours 2 hours, 4 hours, 8 hours, 10 hours, 12 hours, 18 hours Minimum System Lumens 1000 * IP rating of LED Luminaire IP65 IP54, IP65, IP66, IP67, IP68 Ruggedised Storage Box for main equipment Yes * TOWER CONSTRUCTION Maximum of height of Tower/telescopic collapsible mast/Vertical Mast with light source (in meters from base ground level) 1 metre 1 metre, 2 metre, 3 metre, 4 metre, 5 metre, 6 metre, 8 metre Material of Tower/lel escopic/Vertical Mast Stainless steel Aluminium, Mild steel, Galvanised Iron, Fiber, Stainless steel Minimum thickness of Tower/lelescopic collapsible mast/Vertical Mast material (+/-5%) >5 mm * Method of step up and step down of To wer/lelescopic/Vertic al Mast Pnumatic Pnumatic, Hydraulic, Motorised, Winch mechanism Step up and step down time of Tower/lelescopi c/Vertical Mast </=30 sec * The strength of the Tower/telescopic collapsible mast/Vertical Mast tower is to provide support for it to remain erect at wind speed of 50 Km/hr * BATTERY CONSTRUCTION Number of battery 1 * Battery voltage 12 Volt * Battery bank construction shall have inbuilt charging arrangement with charging cables Yes * 2/7 System must have Battery charging arrangement with AC power source input and with DC power source input with necessary cables Yes * Additional charging cable and kits for battery charging from automobile vehicles (Mobile charging option) Yes * Warranty card for battery 1 Year * System shall also work on 220/240V, 50 Hz AC supply and for connecting to the mains shall have provision for 15 Amps 3 Pin/2 pin Socket and a suitable lead wire with plugs at both ends Yes * LED LUMINAIRE CONSTRUCTION LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * LED Modules as per the IS: 16103(Part-2)/2012 Yes * Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50, 000 burning hours as per LM-80 report) >/= 50, 000 burning hours * Colour Rendering Index(CRI) ≥70 * Optic lense materal (UV stabilised) Poly carbonate lense * The Luminaires Yes * 3/7 casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest IP66 * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover/polycarbonate and the metal housing to exclude the entry of the dust, water, insects etc., Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass/poly carbonate cover thickness >/=4 mm * Toughned Glass polycarbonate shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Operating temperature range -20 deg. C to +50 deg. C * "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * 4/7 Date of manufacture (month-year), and lot number as identification mark inside each unit and the outside of each packaging box Yes * REPORTS AND CERTIFICATION Availability of type tet reports from Central Government Laboratory/NABL Accrediated/ILAC Laboratory for complete Portable emergency lighting system including for Engine, Alternator and Luminaires as per relevant IS specifications as applicable Yes * Luminaire System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * Availability for LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government NABL/ILAC accrediated lab. (Reports shall be furnish on demany by buyer/Consignee) Yes * Availability of LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological report for LED report from Central Government NABL/ILAC accrediated lab. (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) (Reports shall be furnish on demany by buyer Consignee) Yes * LED Luminaire shall Yes * 5/7 have Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 or as applicable for portable emergency lighting system as on date Total Weight of complete system (Must declare) in Kg </=5 Kg * Warranty for complete system 1 Year * Storage battery shall have Complusory Registration(CRS) of BIS as per IS 16270 : 2014 as applicable as on date Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 RAJESH MALIK 713148, AIR FORCE STATION PANAGARH PO- BIRUDHIA DIST- BURDWAN 50 15
Loading…