Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
pressure guage for EA set, Providing and fixing of water temperature guage for EA set, Providing and fixing of oil temperature guage for EA set, Providing and fixing of oil pressure guage pipe for EA set, Providing and fixing of LLOP switch for EA set, Providing and fixing of water temperature switch for EA set, Providing and fixing of relay card for start and stop of EA set, Providing and fixing of static AVR suitable for alternator of EA set upto 125 kVA, Providing and fixing of 12 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories, Providing and fixing of 24 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories, Providing and fixing of 2Way centre OFF 40A DP MCB type change over switch, Providing and fixing of Digital RPM cum Hour meter, Providing and fixing of 8 or 11 pin, 12V or 24V DC Pla relay with base, Providing and fixing of 8 or 11 pin, 240V AC Pla relay with base, Providing and fixing of AC Ammeter 96 Sq.mm size and 0 to 200A or 400A range, Providing and fixing of DC Ammeter 72 Sq.mm size and 0 to 50A range, Providing and fixing of AC Voltmeter 96 Sq.mm size and 0 to 500V range, Providing and fixing of DC Voltmeter 72 Sq.mm size and 0 to 50V range, Providing and fixing of 32 Amp 4 pole contactor of AC23 duty, Providing and fixing of 32 Amp contactor coil, Providing and fixing of 63 Amp 4 pole contactor of AC23 duty, Providing and fixing of 63 Amp contactor coil, Providing and fixing of 6 to 32A 10KA C series SP MCB, Providing and fixing of 6 to 32A 10KA C series SPN MCB, Providing and fixing of 32A 10KA C series TPN MCB, Providing and fixing of Ammeter selector switch, Providing and fixing of Voltmeter selector switch, Providing and fixing of Auto manual selector switch, Providing and fixing of VAF plus PF meter with 3No. CTs and its wiring, Repairing servicing of radiator of EA set of 10KVA to 20KVA capacity, Repairing, servicing of radiator of EA set above 20KVA to 62.5KVA capacity, Repairing, servicing of radiator of EA set of 75KVA to 125KVA capacity, Fuel Pump and Injectors caliberation, Repairing of self starter of EA set of 7.5KVA to 32.5KVA capacity, Repairing of self starter of EA set of 45KVA to 125KVA capacity, Repairing of charging alternator, Repairing of high speed exhaust fan upto 450mm dia of EA set canopy, Repairing of EA set canopy door, Repairing of fuel tank of EA set, Replacement of piston with guzzen pin, set of piston ring of 7.5 kVA to 20 kVA EA set, Replacement of piston with guzzen pin, set of piston ring of 25 kVA to 63 kVA EA set, Providing locking arrangement to canopy door, Supplying and fixing of fully charged 1No. New 12V, 88AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. 12V, 88AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery against replacement, P and F of 32A, 240V, 2 Pole ON Load change over switch, P and F of 63A, 415V, 4 Pole front handle operated ON Load change over switch, P and F of 125A, 415V, 4 Pole front handle operated ON Load Bid Details 2/109 change over switch, Dismantling of 7.5KVA to 15KVA canopy or room mounted EA set, Dismantling of 20KVA to 32.5KVA canopy or room mounted EA set, Dismantling of 45KVA to 62.5KVA canopy or room mounted EA set, Dismantling of 100KVA to 320KVA canopy or room mounted EA set, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 1KM to 30KM, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 31KM to 60KM, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 61KM to 120KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 1KM to 30KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 31KM to 60KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 61KM to 120KM, Transportation of old dismantled 100KVA to 320KVA EA set from 1KM to 30KM, Transportation of old dismantled 100KVA to 320KVA EA set from 31KM to 60KM, Transportation of old dismantled 100KVA to 320KVA EA set from 61KM to 120KM, Transportation of old dismantled 100KVA to 320KVA EA set from 121KM to 200KM, Transportation of old dismantled 100KVA to 320KVA EA set from 201KM to 350KM, Providing arranging hydra or crane service for lifting of EA sets, ITC of 7.5KVA to 20KVA EA set, ITC of 25KVA to 32.5KVA EA set, ITC of 45KVA to 62.5KVA EA set, ITC of 100KVA to 320KVA EA set, Providing and fixing of 50MM dia C Class M.S. exhaust pipe, Providing and fixing of 75MM dia C Class M.S. exhaust pipe, Providing and fixing of 100MM dia C Class M.S. exhaust pipe, P and L PCC foundation in ratio 1 as 2 as 4, i.e. 1 Cement, 2 coarse sand and 4 graded stone metal of 20mm NS, Earthing with G.I. earth plate 600mm X 600mm X 6mm thick, P and L earth connection with 6SWG dia G.I. Wire in 15mm dia G.I. pipe, P and F 25mm X 5mm G.I. strip on surface or in recess, Supplying of 3.5 core 150 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 120 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 95 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 70 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 50 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 35 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 2 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable, Laying of cable upto 35Sqmm size direct in ground incl. excavation and refill trench, Laying of cable above 35Sqmm to 95 Sqmm size direct in ground incl. excavation and refill trench, Laying of cable above 95Sqmm to 185 Sqmm size direct in ground incl. excavation and refill trench, Laying of cable upto 35Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable above 35Sqmm to 95Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable above 95Sqmm to 185Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable upto 35Sqmm size in existing masonry open duct, Laying of cable above 35Sqmm to 95Sqmm size in existing masonry open duct, Laying of cable above 95Sqmm to 185Sqmm size in existing masonry open duct, Laying and fixing of cable upto 35sqmm size on wall surface, Laying and fixing of cable above 35Sqmm to 95Sqmm size on wall surface, Laying and fixing of cable above 95Sqmm to 185Sqmm size on wall surface, S and M end termination of 2 X 25sqmm aluminium conductor cable, S and M end termination of 3.5 X 25sqmm aluminium Bid Details 3/109 conductor cable, S and M end termination of 3.5 X 35sqmm aluminium conductor cable, S and M end termination of 3.5 X 50sqmm aluminium conductor cable, S and M end termination of 3.5 X 70sqmm aluminium conductor cable, S and M end termination of 3.5 X 95sqmm aluminium conductor cable, S and M end termination of 3.5 X 120sqmm aluminium conductor cable, S and M end termination of 3.5 X 150sqmm aluminium conductor cable, S and L of 6sqmm. multistrand copper conductor flexible cable incl. copper lugs, P and L of 8SWG dia G.I. wire on surface or in recess, P and L of 40mm dia medium class G.I. pipe in ground, P and L of 100mm dia medium class G.I. pipe in ground
pressure guage for EA set, Providing and fixing of water temperature guage for EA set, Providing and fixing of oil temperature guage for EA set, Providing and fixing of oil pressure guage pipe for EA set, Providing and fixing of LLOP switch for EA set, Providing and fixing of water temperature switch for EA set, Providing and fixing of relay card for start and stop of EA set, Providing and fixing of static AVR suitable for alternator of EA set upto 125 kVA, Providing and fixing of 12 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories, Providing and fixing of 24 Volt 10 Amp SMPS battery charger unit with necessary wires cable and accessories, Providing and fixing of 2Way centre OFF 40A DP MCB type change over switch, Providing and fixing of Digital RPM cum Hour meter, Providing and fixing of 8 or 11 pin, 12V or 24V DC Pla relay with base, Providing and fixing of 8 or 11 pin, 240V AC Pla relay with base, Providing and fixing of AC Ammeter 96 Sq.mm size and 0 to 200A or 400A range, Providing and fixing of DC Ammeter 72 Sq.mm size and 0 to 50A range, Providing and fixing of AC Voltmeter 96 Sq.mm size and 0 to 500V range, Providing and fixing of DC Voltmeter 72 Sq.mm size and 0 to 50V range, Providing and fixing of 32 Amp 4 pole contactor of AC23 duty, Providing and fixing of 32 Amp contactor coil, Providing and fixing of 63 Amp 4 pole contactor of AC23 duty, Providing and fixing of 63 Amp contactor coil, Providing and fixing of 6 to 32A 10KA C series SP MCB, Providing and fixing of 6 to 32A 10KA C series SPN MCB, Providing and fixing of 32A 10KA C series TPN MCB, Providing and fixing of Ammeter selector switch, Providing and fixing of Voltmeter selector switch, Providing and fixing of Auto manual selector switch, Providing and fixing of VAF plus PF meter with 3No. CTs and its wiring, Repairing servicing of radiator of EA set of 10KVA to 20KVA capacity, Repairing, servicing of radiator of EA set above 20KVA to 62.5KVA capacity, Repairing, servicing of radiator of EA set of 75KVA to 125KVA capacity, Fuel Pump and Injectors caliberation, Repairing of self starter of EA set of 7.5KVA to 32.5KVA capacity, Repairing of self starter of EA set of 45KVA to 125KVA capacity, Repairing of charging alternator, Repairing of high speed exhaust fan upto 450mm dia of EA set canopy, Repairing of EA set canopy door, Repairing of fuel tank of EA set, Replacement of piston with guzzen pin, set of piston ring of 7.5 kVA to 20 kVA EA set, Replacement of piston with guzzen pin, set of piston ring of 25 kVA to 63 kVA EA set, Providing locking arrangement to canopy door, Supplying and fixing of fully charged 1No. New 12V, 88AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery, Supplying and fixing of fully charged 1No. 12V, 88AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 120AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 150AH lead acid semi maintenance free battery against replacement, Supplying and fixing of fully charged 1No. New 12V, 180AH lead acid semi maintenance free battery against replacement, P and F of 32A, 240V, 2 Pole ON Load change over switch, P and F of 63A, 415V, 4 Pole front handle operated ON Load change over switch, P and F of 125A, 415V, 4 Pole front handle operated ON Load Bid Details 2/109 change over switch, Dismantling of 7.5KVA to 15KVA canopy or room mounted EA set, Dismantling of 20KVA to 32.5KVA canopy or room mounted EA set, Dismantling of 45KVA to 62.5KVA canopy or room mounted EA set, Dismantling of 100KVA to 320KVA canopy or room mounted EA set, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 1KM to 30KM, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 31KM to 60KM, Transportation of old dismantled 7.5KVA to 32.5KVA EA set from 61KM to 120KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 1KM to 30KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 31KM to 60KM, Transportation of old dismantled 45KVA to 62.5KVA EA set from 61KM to 120KM, Transportation of old dismantled 100KVA to 320KVA EA set from 1KM to 30KM, Transportation of old dismantled 100KVA to 320KVA EA set from 31KM to 60KM, Transportation of old dismantled 100KVA to 320KVA EA set from 61KM to 120KM, Transportation of old dismantled 100KVA to 320KVA EA set from 121KM to 200KM, Transportation of old dismantled 100KVA to 320KVA EA set from 201KM to 350KM, Providing arranging hydra or crane service for lifting of EA sets, ITC of 7.5KVA to 20KVA EA set, ITC of 25KVA to 32.5KVA EA set, ITC of 45KVA to 62.5KVA EA set, ITC of 100KVA to 320KVA EA set, Providing and fixing of 50MM dia C Class M.S. exhaust pipe, Providing and fixing of 75MM dia C Class M.S. exhaust pipe, Providing and fixing of 100MM dia C Class M.S. exhaust pipe, P and L PCC foundation in ratio 1 as 2 as 4, i.e. 1 Cement, 2 coarse sand and 4 graded stone metal of 20mm NS, Earthing with G.I. earth plate 600mm X 600mm X 6mm thick, P and L earth connection with 6SWG dia G.I. Wire in 15mm dia G.I. pipe, P and F 25mm X 5mm G.I. strip on surface or in recess, Supplying of 3.5 core 150 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 120 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 95 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 70 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 50 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 35 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 3.5 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable, Supplying of 2 core 25 Sq.mm. size ISI mark aluminium conductor armoured cable, Laying of cable upto 35Sqmm size direct in ground incl. excavation and refill trench, Laying of cable above 35Sqmm to 95 Sqmm size direct in ground incl. excavation and refill trench, Laying of cable above 95Sqmm to 185 Sqmm size direct in ground incl. excavation and refill trench, Laying of cable upto 35Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable above 35Sqmm to 95Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable above 95Sqmm to 185Sqmm size in existing RCC or HUME or METAL pipe, Laying of cable upto 35Sqmm size in existing masonry open duct, Laying of cable above 35Sqmm to 95Sqmm size in existing masonry open duct, Laying of cable above 95Sqmm to 185Sqmm size in existing masonry open duct, Laying and fixing of cable upto 35sqmm size on wall surface, Laying and fixing of cable above 35Sqmm to 95Sqmm size on wall surface, Laying and fixing of cable above 95Sqmm to 185Sqmm size on wall surface, S and M end termination of 2 X 25sqmm aluminium conductor cable, S and M end termination of 3.5 X 25sqmm aluminium Bid Details 3/109 conductor cable, S and M end termination of 3.5 X 35sqmm aluminium conductor cable, S and M end termination of 3.5 X 50sqmm aluminium conductor cable, S and M end termination of 3.5 X 70sqmm aluminium conductor cable, S and M end termination of 3.5 X 95sqmm aluminium conductor cable, S and M end termination of 3.5 X 120sqmm aluminium conductor cable, S and M end termination of 3.5 X 150sqmm aluminium conductor cable, S and L of 6sqmm. multistrand copper conductor flexible cable incl. copper lugs, P and L of 8SWG dia G.I. wire on surface or in recess, P and L of 40mm dia medium class G.I. pipe in ground, P and L of 100mm dia medium class G.I. pipe in ground
2 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.