Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
No organisation data
Try another outcome or period.
No state data
Try another outcome or period.
Submersible Pump Set Three Phase Submersible Pump Set Three Phase ( 15 ) Technical Specifications Specification Specification Name Values Allowed Values GENRIC Conformity to Indian Standrad for Submersible Pump Set ISI Marked Submersible Pumpsets to IS:8034 latest for use in borewells for handling clear cold water having ISI Marked motor to IS:9283 latest of wet type for continuous rating synchronous, Cat egory-B, Duty Type-S1 - Bore Size 150 - Delivery Size 50 - CONSTRUCTION Nos of Stages for submersible pump 10 - Pump shaft Stainless steel grade X 04 Cr 12/X 12 Cr 12 X 20 Cr 13 of IS 6603 - Shaft Sleeve 12 % chromium steel grade X 04 Cr 12/X 12 Cr 12 and X 20 Cr 13 conforming to IS 6911 or IS 6603 - Suction Casing Cast iron grade FG 200 of IS 210 - Casing wear ring (if provided otherwise N/A - 1/4 choose N/A) Bush Bronze grade LTB 2, 3, 4 or 5 of IS 318 or Nitrile cutless rubber - Discharge casing (if provided otherwise choose N/A) Cast iron grade FG 200 of IS 210 - Impeller Stainless steel grade X 12 Cr 12 of IS 6911 or IS 6603 - Maximum outer diameter of the pumpset including the cable guard 5 - Details of Power Supply Three Phase, 415 V +6 %, 15%Volts, 50Hz±3% Hz - Type of motor ISI Marked to IS:9283 latest of wet type for continuous rating synchronous, Type B, Duty Type-S1 - Numbers of poles of motor 2 pole - Motor rating 4.5 As per GeM Catalogue. Maximum current at rated voltage and frequency 12 As per GeM Catalogue. Control Pannel with starter, ISI marked MCB main switch, ammeter, voltmeter and water level indicator and single phase preventer Yes - Non return valve Yes - Erection clamp Yes - ISI marked submersible cable 4 core flat with Copper conductor to IS: 694 3 - PERFORMANCE Discharge capacity (LPS) 2 2 Discharge Head 100 100.0, 90.0 Speed of Pump (rpm) 2800 - BEE Energy Star Rating 5 Star - Overall Efficiency of Submersible Pump Set at duty point (%) 100 - 2/4 Performance Factor of the Pump Set >= 1.20 for 5 star - Weight of Pump set 35 - CERTIFICATION BIS CM/L number and validity of ISI marked Submersible Pump Set - - Availability of Type Test Report to prove conformity of parameters to the specification from any ILAC/NABL accredited/Central Govt lab YES - Test certificate No and date - - Name of the Lab where test Conducted - - Test Report to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Samar Bahadur Singh 497229, O/o Executive Engineer, Public Health Engineering Division, Surajpur 15 15
Submersible Pump Set Three Phase Submersible Pump Set Three Phase ( 15 ) Technical Specifications Specification Specification Name Values Allowed Values GENRIC Conformity to Indian Standrad for Submersible Pump Set ISI Marked Submersible Pumpsets to IS:8034 latest for use in borewells for handling clear cold water having ISI Marked motor to IS:9283 latest of wet type for continuous rating synchronous, Cat egory-B, Duty Type-S1 - Bore Size 150 - Delivery Size 50 - CONSTRUCTION Nos of Stages for submersible pump 10 - Pump shaft Stainless steel grade X 04 Cr 12/X 12 Cr 12 X 20 Cr 13 of IS 6603 - Shaft Sleeve 12 % chromium steel grade X 04 Cr 12/X 12 Cr 12 and X 20 Cr 13 conforming to IS 6911 or IS 6603 - Suction Casing Cast iron grade FG 200 of IS 210 - Casing wear ring (if provided otherwise N/A - 1/4 choose N/A) Bush Bronze grade LTB 2, 3, 4 or 5 of IS 318 or Nitrile cutless rubber - Discharge casing (if provided otherwise choose N/A) Cast iron grade FG 200 of IS 210 - Impeller Stainless steel grade X 12 Cr 12 of IS 6911 or IS 6603 - Maximum outer diameter of the pumpset including the cable guard 5 - Details of Power Supply Three Phase, 415 V +6 %, 15%Volts, 50Hz±3% Hz - Type of motor ISI Marked to IS:9283 latest of wet type for continuous rating synchronous, Type B, Duty Type-S1 - Numbers of poles of motor 2 pole - Motor rating 4.5 As per GeM Catalogue. Maximum current at rated voltage and frequency 12 As per GeM Catalogue. Control Pannel with starter, ISI marked MCB main switch, ammeter, voltmeter and water level indicator and single phase preventer Yes - Non return valve Yes - Erection clamp Yes - ISI marked submersible cable 4 core flat with Copper conductor to IS: 694 3 - PERFORMANCE Discharge capacity (LPS) 2 2 Discharge Head 100 100.0, 90.0 Speed of Pump (rpm) 2800 - BEE Energy Star Rating 5 Star - Overall Efficiency of Submersible Pump Set at duty point (%) 100 - 2/4 Performance Factor of the Pump Set >= 1.20 for 5 star - Weight of Pump set 35 - CERTIFICATION BIS CM/L number and validity of ISI marked Submersible Pump Set - - Availability of Type Test Report to prove conformity of parameters to the specification from any ILAC/NABL accredited/Central Govt lab YES - Test certificate No and date - - Name of the Lab where test Conducted - - Test Report to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Samar Bahadur Singh 497229, O/o Executive Engineer, Public Health Engineering Division, Surajpur 15 15
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.