Loading…
Loading…
948 results • Best match
HVAC works
Design, Supply, Installation, Testing And Commissioning of HVAC System on 5th Floor at Golden Jubilee Block, Poojappura, Thiruvananthapuram - CAMC Rate in Rupees/Year
HVAC System for Janki Devi Memorial College Library, New Delhi
Testing, Adjusting and Balancing (TAB) and Commissioning of the complete VRF/VRV HVAC system including but not limited to: (a) verification of refrigerant charge in each circuit using sub-cooling/super-heat method and electronic leak detection at all brazed joints and flare connections; (b) airflow measurement and balancing at each supply air diffuser and return air grille using calibrated balometer/anemometer to achieve design CFM within ±10% tolerance; (c) duct leakage testing of main duct runs to SMACNA Class-A seal standard; (d) measurement and recording of supply air temperature, return air temperature, and room temperature at each indoor unit at steady-state conditions; (e) verification of condensate drain flow from each indoor unit; (f) verification of BMS/fire shutdown signal response from each indoor unit; (g) verification of central controller communication with all 17 indoor units; (h) noise level measurement at representative occupied spaces (target NC-35 for reading areas, NC-40 for office/stores); (i) preparation and submission of detailed TAB report with all measured values in tabulated format, instrument calibration certificates, and as-built system performance data. All instruments used shall have valid calibration certificates. — 1 L.S.
Operation and AMC of VRF type HVAC systems installed at Albert Hall, Jaipur
Providing experienced and Highly skilled/skilled/ semi-skilled/Un Skilled labour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month) from 8.am to 8.30 PM
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - AIRPORT; HVAC; NA
and Installation of Plant Systems/Equipments (Version 2) - AIRPORT; HVAC; NA
SH- Special repair and replacement of damaged part and compressor oil Chiller No. 02 and No. 05
Providing Special repair to the Chiller No 2 and 5 including SITC of Compressor oil and other damaged parts to make them fully operational. The cost included the cost of Compressor oil , Oil Filter , refrigerat Filter , Refrigerant dryer , Oil Strainer and sensor Etc in water cooled cetrifugal Type 470 KW comressor and 700 TR capacity Chiller No 2 and 5 of existing HVAC plant complete in all respect Make: CARRIER
Repair and Renovation of damaged false ceiling with HVAC ducting along with whole electrical installation work including DG Set and Compound light at Rabindra Bhawan, Bankura.-------Repairing and Servicing of HVAC System.