Loading…
Loading…
2,042 results • Best match
PROVN OF STN STORES AND ADDN/ALTN OF BATHROOM ANDOH SHED AT MAIN GATE, EXTERNAL PATHWAY FLOOR AND GARAGES AT MD ACCN AT ASHOK VIHAR AND PROVN OF HARD STANDING NEAR SUPPLY MORH AND LT PANELS, DB BOXES A/W ELECTRICAL FITTING TO BLDG NO P-11 UNDER GE
Supply, Installation, Testing and commissioning of 11KV VCB Panel and other allied works for providing dedicated/independent 11KV feeder to BSF campus Nowshera on turnkey basis.
Supply, Installation, Testing and Commissioning of 11KV VCB Panels and other allied equipment at 33/11KV Receiving Station GMC Rajouri on turnkeybasis.
REPAIR MAINTENANCE REPLACEMENT OF DBs TPN MCB MCCB EARTHING LIGHTANING CONDUCTOR ROOF LIGHTS AND CONNECTED WORKS UNDER AOR OF GE SAMBA
Replacement of MCCB of unit II along with other minor repair at LIS Zanihal. Shifting of recovered machinery after flash floods from LIS Balole.
Providing and fitting of 250 ampere MCCB-1no. DOL starter 10 ampere-1no. 200 ampere2no. at pumping station Garnai, Rakh Badali and Urlian Garnai.
Replacement of damaged 400 Amp capacity MCCB of 517 CFM Air Compressor of 800 LPM Oxygen Plant installed at Govt. Super Specialty Hospital, Srinagar.
Providing and filling of transformer oil and repairs/replacement of MCCB of oxygen plant and replacement to damaged motors at Govt. LD Hospital Srinagar.
REPAIR MAINT OF DG SETS LOCATED AT VARIOUS LOCATIONS OF AF SN AS SUCH TECH AREA, UPPER CAMP AND LOWER CAMP INCLUDING REPAIR TO AMF CONTROL PANEL, ATS AND CERTAIN MISC EM WORKS AT 39 WING AF STN UDHAMPUR
Supply,Installation,Testing and Commissioning of 11 KV Indoor Switchgear to be installed at Receiving Station Tikker For Construction Of Dedicated 11 KV Feeder For District Jail Kupwara
Supply,Installation,Testing and Commissioning of 11 KV Indoor Switchgear to be installed at Receiving Station Achabal for Construction of Dedicated Outgoing 11 KV Feeder for Achabal Hatchery.
Stabilization / Improvement of various 33/11 KV Receiving Stations by way of replacement of damaged/ dysfunctioning equipment ,up gradation of switchgear protection system in District Kishtwar and Thathri.
Repair/Replacement pipeline control valve pumping system and switchgear installed at Command HQ area, PB enclave, Alpha Mess, PH, MT PH and Sappers Enclave under GE Utilities Udhampur
Supply ,installation, testing and commissioning of 11KV VCB Panels and other allied equipments at MES Kamsar Poonch on turnkey basis.
Supply Installation Testing And Commissioning Of 11KV VCB Panel At Receiving Stations Preng, Nahidal And Manigam under Capex Budget 2021-22.
REPAIR AND MAINTENANCE OF HT OH/UG LINE, TRANSFORMER, VCB, HT CABLES AND CERTAIN WORK UNDER GE (ARMY) DHAR ROAD UDHAMPUR
Repair and maintenance of incomer VCB panel-II 800 Amp 6.6 KV 25 kA 250 MVA installed at Tawi Pump house
REPAIR/MAINT OF HT UG CABLE, HT BREAKERS VCB,VOLTAGE STABILIZERS AND CONNECTED WORKS AT WATER SUPPLY UNDER GE (UTILITIES) UDHAMPUR
Repairs and restoration of 11 KV, VCB Panel installed at Water Supply Tangnar Stage-2nd. feeding power to the Filtration Plant.
REPAIR/MAINTENANCE OF DG SETS LOCATED AS VARIOUS LOCATIONS OF AF STN AS SUCH TECH AREA, UPPER CAMP AND LOWER CAMP INCLUDING REPAIR TO AMF CONTROL PANEL, ATS AND CERTAIN MISC E/M WORKS AT 39 WING AF STN UDHAMPUR
Providing Fitting of New Submersible Pumpset (15000 GPH 40 m Head 20 H.P induction motor Voltage Stabilizer 63 kVA and Electric Control Panel 20 HP 3 Phase Star Delta and Recapitalization of 63 kVA Electric Transformer at Tube Well Chatha D in Bloc
Repair to 15000 GPH x 250 meter head HC pump motor set of pumping station Thill Roun and replacement of damaged / wornout components alongwith allied works of 415v,3 phase, 300 ampere LT control panel cum fault analyzer unit installed at pumping stat
Repair/Maint of Pumps, Motors, Starters, Control Panel, Relays, Filt Plant, RO, Solar Water Heating Sys and EWS System, cleaning of water tank of various cap and misc connected items at Ramban, Banihal, Patnitop and Nathatop Area Under GE (I) 873 EWS
Providing, Installation, testing and comm. of HC pump set of 8000 GPH x 325 mtr head as standby along with allied works and LT control panel of 110 amp at T/well cum P/Stn. Koullad in Birpur section under UT capex Budget
Installation, Testing Commissioning of HCP set 6000 GPH X 325 MH X 60 HP , 150 KVA manual voltage stabilizersand providing/fitting SPS 6000GPH X 60 MH x 25 HP, control panel 60 HP and 25 HP at Pumping station BasooniDharanaBorewell under WSS Brella
Repair to 5000 GPH x 250 meter head pump motor set of unit no 2 installed at pumping station Dhema and replacement of electro-mechanical components of 110 ampere rating 415v, 3 phase, LT control panel at pumping station Pathwar stage-1st .
Supply, Installation, Testing and Commissioning of split type ACs (conference Hall) at Anti-Corruption Bureau Police station Anantnag Awantipora.
please refer BOQ
Supply, Installation, Testing and Commissioning of split type ACs at Anti-Corruption Bureau Police station Awantipora.
DHE BEST 1250 A 4 Pole 50 KA Molded Case Circuit Breakers, DHE BEST 1250 A 4 Pole 50 KA Molded Case Circuit Breakers (Mccb)
DHE BEST 1250 A 1 Pole 35 KA Molded Case Circuit Breakers, DHE BEST 1250 A 1 Pole 35 KA Molded Case Circuit Breakers (Mccb)
Replacement of 250-amp MCCB, providing and fitting of new coupling to feed pump of 20 lackcal/hr along with allied works at Govt.LDHospital, Srinagar
Replacement by way of providing and fitting of 630 ampere MCCB of unit no. 1, 5 and 6 at pumping station Salmay stage-1st (Old).
Repair/Maint of underground elect cable,LT Panel, LT line and connected work at 57 WEU, 874 alongwith connected units in AoR of RAC Section and Repair/Maint of LT line, UG cable alongwith connected works at unit located near to old medical complex un
Supply,Installation,Testing and Commissioning of 11 KV Indoor Switchgear to be installed at Receiving Station Tikker For Construction Of Dedicated 11 KV Feeder For Industrial Estate Brainwari Kupwara
PROVN OF EXTERNAL ELECTRIC SUPPLY AND LT PANELS AT VICTOR AWANTIPUR UNDER GE 861 EWS
Supply, Installation, Testing and Commissioning of 11 KV VCB Panels for various Receiving Stations of STD Sopore under Capex Budget 2024-25.
Repair/maint of HT UG cable, HT breakers VCB,transformers and connected electrical works at water supply installation under GE (Utility) Udhampur
SITC of 11kV VCB panel along with allied equipment for Water supply Scheme Muradpora Canal Colony Mangnipora Bandipore at Receiving Station Aloosa.
AMC for 11 kv vaccum circuit breaker HT panel board at New Campus
MCB distribution board in sheet metal enclousre 4 ways double door, white cover plate with frame module, Metal flux box 6 module, Plastic body wall mounting fan 400 mm sweep, Cable PVC insulated unsheathed Twin core flexible copper conductor 1100V grade of size 1 and half Sqmm, MCB single pole 230V AC 50 Hz 16 Amps 10KA confirming to IS 8828 1996 IEC 60898 2002 suitable for lighting and other domestic loads, Modular socket 6A 2 3 pin combined 2 module, White cover plate with frame 2 module, Metal flush box 3 Module, Metal flush box 2 Module, PVC casing caping pipe 25mmx16mm 2 Mtr Long, PVC Casing caping square box 4 inch X 4 inch, PVC Body Exhaust fan 200mm sweep with lowers, LED Tube light fitting 1 x 9W 2 feet long complete with all accessories including LED tube rod, MCB distribution boards in sheet metal enclosure 2 ways double door with blanks confirming to IS 8623, Aggregate 20mm, Natural Sand, Water proofing silica panels of size 300x300mm x 7or 8 mm thick, 20mm Socket suitable for 20mm dia PP R pipes Conforming to IS 1239 1989, Bib cock 20mm with flange, Rotational moulded polyethylene water storage tank double layer cylindrical vertical tank 1000 ltrs capacity as per IS 12701 of 1996 along with manhole lid of same material of the tank, PPR tank connector 20mm with check nut and washer, White lead safeda, PPR Reducer socket 15 20mm, PPR Reducer elbow 15 20mm, Vitreous china wash Hand Basin WHB white flat back size 550x400 mm, 4 inch dia UPVC bend, Drilling machine portable type electrically driven, Aluminum straight edge 50mm square 2mm thick 1800mm long, Wooden Flat Gurmala, Hand rivet gun machine, Tile cutter machine with 6 spare blades each, Tasla Iron 18 inch, Shovel with wooden handle, Brick hammer 1200 grams, Cutting plier insulate 6 inch, Screw driver 12inch with insulated plastic handle, Adjustable spanner 12inch, Hacksaw frame with 2 blade, Hand gloves insulated with 2 rubber, Drill bit 6mm dia, Drill bit 8mm dia, Drill bit 10mm dia, Tape measuring metallic 30m, Mason trowel Karchi, Axepicks with wooden handle, Fawda with wooden handle, Crowbar 5feet long, Hammer with wooden handle of wt 5 Kg, Pipe wrench 12 inch, Pipe wrench 18 inch, Aluminum spirit level 6 inch, Brick Line, Sieve for sieving fine and corse agg 900x1500mm made of angle iron frame with stand, PPR Welding Machine 20 to 63mm with cutter and accessories. BOQ Title BoQ bidding
REPAIR MAINT REPLACEMENT OF DB TPN MCB MCCB AND CONNECTED ITEMS INCLUDING EARTHING LIGHTENING CONDUCTOR FLAME ROOF LIGHTING UNDER AOR OF GE SAMBA
AUGMENTATION OF 04 POLE 11 KV POWER SYSTEM INTO RMU FOR GOLF VIEW ENCLAVE AND SPL REPAIR/ REPLACEMENT OF HT OVERHEAD CONDUCTOR INTO UG CABLES FROM MPH TO 9 PARA (SF) UNDER GE (UTILITIES) UDHAMPUR
CA NO CWEAFJ-47/2025-26 COMPREHENSIVE MAINTENANCE OF VCBs, GOD, RMU, HT BUS BAR LBS OF 11 KV AND OTHER ALLIED WORKS AT VARIOUS LOCATIONS AT AIR FORCE STATION UDHAMPUR UNDER GE (AF) UDHAMPUR
Development of site and bulk services including Sewer Lines Road Work Patrolling Path along Boundary Wall Water Supply Sump Well STP and Tube Well etc. E and M services and Horticulture work for CRPF Campus GC Hiranagar at Kootah Distt. Kathua J and ... for HT Panels .
REPAIR / MAINT INTERNAL E/M FITTINGS AND FIXTURES, DBS, SUB MAIN, MCCB, INTERNAL ELECTRIFICATION WORKS AT CHINAR AREA UNDER AGE E/M OF GE (NORTH) UDHAMPUR
Repairs to 300 HP ATS starter of lift irrigation scheme Janbazpora-II, 300 HP motor of LI.S Janbazpora-I and 250 Amp MCCB of L.I.S Azadpora.
Replacement of damaged 200 ampere MCCB along with allied works at pumping station Urlian Garnai and control valves along with allied works at pumping station Krimachi.
REPAIR / MAINT INTERNAL E/M FITTING AND FIXTURES, DB, SUB MAIN, MCCB, INTERNAL ELECTRIFICATION WORK AT PB ENCLAVE UNDER AGE E/M OF GE (NORTH) UDHAMPUR.
PROVIDING AND FITTING OF 2 CUSEC PUMPING UNIT WITH BASE FRAME,225 HP FASD STARTER,400A MCCB, ELECTRIFICATION WITH ALLIED WORKS AT LIS ZEHANPORA (Pumping unit).