Loading…
Loading…
2,821 results • Best match
Laying of Additional circuit of AB cable in 21 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.
Laying of Additional circuit of AB cable in 24 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.
Laying of Additional circuit of AB cable in 16 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.
Laying of Additional circuit of AB cable in 14 Nos. of various feeder under KESCo., Kanpur
Laying of AB Cable (3x120+1x95+1x16) Sq.mm Including (All Fitting Accessories Providing & Fixing By Contractor M.S.Holding Clamp PCC, M.S. Holding Clamp 4.5"/ 5.5" 50x6 mm, Suspension Clamp With I Hook, Dead End With I Hook,Pericing Connector 120-120 mm, Neutral Connector,Dead End Seeling Cap,NUT Bolt With Double Washer.)As per Technical standard Approved by Kesco/ Uppcl.
33 KV Cable Laying, 11 KV Interlink, Line Repairing and other associates work EDD-I, Bahraich
Erection work Minium depth of laying from ground surface to the top of cable as per IS is- i) Low Voltage (1.1 KV) and Control Cable - 0.75 Mtr. ii) 3.3 KV to 11 KV Cables - 0.90 Mtr. iii) 22 KV to 33 KV Cables - 1.05 Mtr. iv) Cables at Road Crossing - 1.00 Mtr. v) Cables at railway level crossings (measured from bottom - 1.00 Mtr. of sleepers to the top of Pipe) Note 1) - The depth may be increased but not more than 1.6 M 2)- The standard depth and width for laying the cable are also attached (as per letter No. 561/Director(Tech.)/MVVNL/Camp/Dt. 09-01-26 561 with the tender form.
Tender for U/G OFC Cable Laying works (2 Nos OFC routes for 17.2 KM in Bhongiri Zone under Nalgonda BA
e-Tender for U/G OFC Cable Laying works (2 Nos OFC routes for 17.2 KM) in Bhongiri Zone under Nalgonda BA