Loading…
Loading…
17,028 results • Best match
SPECIAL REPAIR TO UNSV STREET LIGHT
Supply, laying and testing cable XLPE Insulated ,screened, ...
DRILLING OF BOREWELL AND 5HP MOTOR IN POOCHIATHIPEDU AT POOCHIATHIPEDU PANCHAYAT IN ELLAPURAM PANCHAYAT UNION
Laying of LT Cable Weir 4Sq.mm P142(WD-M1984)-12.2-1
MAINT AND REPAIRS TO SECURITY LIGHTS SOLAR LIGHTS OF ANY TYPE BOLLARD AND HIGH MAST LIGHTS LIGHT POLES AND CONNECTED ITEMS AND CONNECTED REPAIRS
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in hard/dense soil for laying of UG cables all as specified and as directed.
TNO.04/EDC2MT/2026-27
Laying of underground 11 KV XLPE Cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per Respo
CONSTRUCTION OF 4 NO 33 KV FEEDER FROM NEW 132/33 KV SUB-STATION KHATIMA(U.S.NAGAR)
... 0.60x0.15 x1.5 mtr. and laying of underground 33 KV XLPE cable with making of brick housing ...
REPAIR REPLACEMENT OF SLUICE VALVE PPR PIPE LINES GATE VALVE ATTENDING DAY TO DAY WS COMPLAINTS CLEANING OF UG SUMP RESERVOIR MOTOR BREAK DOWN COMPLAINTS, REPAIR TO ROOF SHEET FALSE CEILING ELECTRICAL FITTINGS FIXTURES OF DAD UG CABLE PANEL BOARD SWI
Supply, laying and testing cable XLPE insulated, screened, ...
Construction of Kalyan Mandap at Gurundia
Laying of MV cable up to 25 sqmm in Ground (5.1.1)
HANSDIHA - Provision of DC track circuit in parallel with existing MSDAC at HSDA for dual detection to improve reliability
Item- 4 Trenching & Cable Laying
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS GEYSERS SOLAR WATER HEATERS CONDUIT DUCT FOR ELECTRICAL COMMUNICATION MEDIA CABLES SUBMAIN WIRING MAIN DBS UNSV MCBS BLDG EARTHING AND CERTAIN MISC EM WORKS AT AFTC 2 DC AREA CQAE WE
... refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned ...
REPAIRS REPALCEMENT OF OLD UNSV RUSTED PIPE LINE ,PUMP MOTOR , CLEANING OF OVER HEAD TANK AND CONNECTED WORKS OF EXTERNAL WATER SUPPLY REPAIR MAINTENANCE TO LT EXTERNAL ELECTRICFICATION REPAIRS MAINT SERVICING TO COOLING APPLIANCES REPAIR MAIN
... layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including ...
NCTPS I ES Circle EM II Dn SM S Dn Camp FOC Carrying out Time bound maintenance works of Camp FOC for a period of 360 days by engaging works contract at NCTPS I
Earth work excavating the hard red & stoney earth & depositing on bank for laying of LT cable, providing fly ash cushion and covering the cables with fly ash bricks and refilling the earth.
Replacement of ACSR conductor of LT line by AB cable in 11 KV Nodi feeder under EDSD Thalisain under EDD Nainidanda on Semi Turnkey basis
Laying of AB cable 1x16+25 sq.mm
Salvaging of Various Electrical equipment in different places of Madhaipur Colliery and Installation of 500KVA,11KV/550V Transformer at Madhaipur Colliery
Cable Dismantaling ,Shifting Laying & Connection on pole
Installation of 250 KVA T/F at near Bami MandirC-15Naryan Vihar Shimla bypass, Near Munni CK C15 Turner Road, Near Oslinline chota Bharuwala, Near Capital Avenue C-19 Turner Road, LN 2 Sankriti Lok Colony Tuner Roadand LN5EIISanskriti Lok Colony
LAYING OF AB CABLE OF SIZE 120SQMM
Increasing Capacity work of Power T/F (No. 01) from 8 MVA to 12.5 MVA under 33/11 KV S/S Amritpur Patti, EDSD(First), Jaspur under the Head of Capital (SI).
Laying of Control cable
Maintenance of overhead line illumination from 23/8 incline mine to 23/8 WB with Flat light fitting under E.J. Area
Supply & Drawing Laying of AB cable
Installation of one no. 350 mtr head 1000 GPM pump with 425 KW motor with all valves and bends and pipe at 75L/13D at LHCM1 section in RVIIA seam of 3and4 Incline UG of Jhanjra Project Colliery
... the help of haulages and laying / hanging this cable from sub-station to VCB.
Electro mechanical works
Installation of Panel with laying of the cable including making all electrical connection complete as per direction including supply of necessary materials as required for the work.
Contract for Dismantling Fabrication Erection of Batala CSM
Dismantling & laying HT & LT cable with tray and termination Kit.
Replacement of ACSR conductor of LT line by AB cable in 11 KV Bheeda feeder under EDSD Thalisain under EDD Nainidanda on Semi Turnkey basis
Laying of AB cable 1x16+25 sq.mm
20/EDCG/2026-27
LAYING OF CONTROL CABLE VCB TO CONTROL ROOM
SHIFTING OF LINES AT KUNTI NAALA ON REQUEST OF IRRIGATION DEPARTMENT UNDER DEPOSIT HEAD
LAYING OF AB CABLE OF SIZE 120 SQMM.
Increasing Capacity Installation of New DTR work of 08 No. Different DTR on Avas Vikas, Gandhi Park Feeder under 33/11 KV S/S Jaspur, EDSD(First), Jaspur under the Head of Capital (SI).
Laying of AB cable of size 120 Sqmm
Providing, fixing and installation of electric fencing at store of 400KV Substation Rishikesh
... LIKE POWER POINT ARRGEMENT LAYING OF POWER CABLE AT DIFFERENT LOCATIONS INCLUDING ...
Construction Of additional 11KV Line from 33/11KV S/s Guptkashi To Fata under Capital head on Semi Turnkey Basis
LAYING OF 11KV CABLE IN TRENCH ALL WORKL
PROVIDING INFRASTRUCTURE FACILITIES AT MAIN MARKET YARD OF APMC BILAGI UNDER RIDF-31 SCHEME-2025-26
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.
SPECIAL REPAIR TO BLDG NO A29 MEDICAL STORE OF 417 FD HOSP AT RHENOCK UNDER GE 867 EWS
... 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all ...
REPAIR MAINTENANCE OF STREET LIGHTS HIGH MAST LIGHTS PERIMETER LIGHTS INCL ALLIED WORK AT SECTOR B2 UNDER GE UTILITY AMBALA CANTT
... of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth ...
REPAIR AND MAINT OF LT ELECTRIC DISTRIBUTION SYSTEM AT SECTOR B2 UNDER GE UTILITY AMBALA
... of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth ...
REPAIR AND MAINT REPLACEMENT OF LT ELECTRIC OVERHEAD UNDERGROUND NETWORK SYSTEM INCL ALLIED WORKS AT SECTOR B1 UNDER GE UTILITY AMBALA
... of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth ...
REPAIR MAINTENANCE OF PERIMETER SECURITY LIGHTS STREET LIGHTS AND HIGH MAST LIGHTS INCL ALLIED WORK AT SECTOR B1 UNDER GE UTILITY AMBALA CANTT
... of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth ...
REPAIR/MAINT OF JOUNCTION BOX, LT PANEL, LT CABLES, DISPERSAL LIGHTS, SIGN BOARDS, STREET LIGHT/SECURITY LIGHT JUNCTION BOXES, TIMES SWITCHES, LT CABLE, HIGH MAST LIGHTS, HANGAR LIGHTS, AVIATION LIGHT, BLAST PAN LIGHTS AND OTHER CONNECTED WORK AT TEC
... 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all ...
CONSTRUCTION OF RANGA MANDIRA AT BONDEL IN MCC LIMITS
Laying of cable in Existing Trench/GI pipe/Stone ...
SPL REPAIR OF OTHER RANK LIVING ACCOMMODATION BLDG NO TO 243 OF 203 ARMY AVN SQN UH UNDER AGE BRI OF GE 865 EWS LEH
M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified.
Special Structural Repair and Retrofitting work in Rajasthan High Court Building, Jodhpur (Security and Operating system for LAN and CCTV Works)
Supplying and Laying coaxial cable 75 ohm impedance with foam ...
REPAIR/ REPLACEMENT OF LT CABLE, OH LINE AND CONNECTED ALLIED WORKS UNDER GE SAUGOR
... cable , 80 mm thick before laying the cable and 150mm thick after laying the cable complete all as specified ...
PROVN OF 02 X TOILET BLOCK, 2 X BATHROOM ALONGWITH CONNECTED SANITARY FITTING SYSTEM AT PINE BAKERY OF 509 ASC BN UNDER AGE B/R-III AND AGE E/M-II OF GE (SOUTH) MEERUT CANTT.
... trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling ...
SPECIAL REPAIR TO BLDG NO T-88 OF ASC COY KHALSAR AND SPECIAL REPAIR TO BLDG NO T-29 OF 71 OMP AT KHALSAR UNDER GE 873 EWS
... exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm ...
As described in Bill of quantities
... layer of 80mm thick before laying of cable and second layer 150mm thick after laying of cable and punned down to 180 mm ...
SPECIAL REPAIR TO BLDG NO 102/1 and 102/2 (GUN SHED) OF 43 FD REGT UNDER AGE B/R-IV AND AGE E/M-II OF GE ( SOUTH) MEERUT CANTT.
... trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling ...
Upgradation of street lights and Providing and fixing of High Mast lights at IGP hattipura, Bundi
... mm along the trench, (b) Lay the cable in the middle of the trench,... height 125 mm on top of the cable, (d) Lay the protective Common burnt ...
as per boq
... mm along the trench, (b) Lay the cable in the middle of the trench,... height 125 mm on top of the cable, (d) Lay the protective Common burnt ...
SPECIAL REPAIR TO RAISING MAIN PIPELINE WITH CONNECTED FITTING FIXTURE AND OLD VINTAGE SECURITY LIGHT PANEL AND OTHER CONNECTED WORK AT CERTAIN PLACES OF AFTC AND AFS JALAHALLI
... refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned ...
Signal Zonal work under the jurisdiction of SSE/SIG/CHE in Visakhapatnam Division.
... Guidelines on Signalling Cable laying given by RDSO and any latest ...
Signalling work in connection with " Development of Infrastructure facilities for Track Machine Siding in Solapur Division of Central Railway."
... plan and refilling after cable laying. This work includes covering ...
SPECIAL REPAIR AND ALLIED SERVICES TO BLDG NO T-29 AND T-31 AT JOSHIMATH UNDER GE 871 EWS.
... cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall ...
ADDN ALTN REPLACEMENT OF ASBESTOS SHEETS AND FALSE CEILING OF CERTAIN BLDGS UNDER GE AF MOHANBARI
Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, ...
Construction of Cold Storage under RIDF-31 Scheme 2025-26 at Five different Locations namely Kundagola MMY, Sindagi MMY, Hosadurga Main Market Yard and Rona(Holealur APMC)SMY, Habbanaghatta Kaval(Arasikere APMC) Sub Market Yard
Laying of cable in Existing Trench/GI pipe/Stone ...
Upgradation of Power lines infrastructure at industrial area Karauli
... mm along the trench, (b) Lay the cable in the middle of the trench,... height 125 mm on top of the cable. (d) Lay the protective Common burnt ...
development and beautification of ghodo ka chok circle jodhpur
... mm along the trench, (b) Lay the cable in the middle of the trench,... height 100 mm on top of the cable, (d) Lay the protective Common burnt ...